XHCY

 信合创元电气

公司简介 行业业绩 产品信息 技术服务 应用实例 反  馈 联系信息

 


   应用实例...


   备件服务...


欧陆仪表...

2200系列

2400系列

26/2700系列

3200系列

3500系列

 

欧陆调功器...

7100L/S/A

7300A

 

欧陆直流调速器...

ER-PL(PLX)

功率扩展单元

ER-340/680/1220

ER-3200/3600

 

欧陆自动化...

T2550

 


西门子调速器...

6RA70系列

 


 

欧陆直流传动...

512C/514C

590C

590+

 

欧陆交流传动...

650

690+

 

欧陆伺服系统...

631

635

 


 

ABB直流传动...

DCS400

DCS500B

DCS800

 

ABB交流传动...

ACS400

ACS550

ACS800

ACS1000

 


 

直流调速扩展单元

 

 

直流调速扩展单元

 

 

The PL/XD is used for controlling external 3 phase thyristor stacks for DC motors, and possesses all the
functionality of the PL/X range. It is in the same package as the PL/X 5 - 50 models.


       The PL/XD provides gate drive pulses for driving user supplied pulse transformers with primary pulse current
up to 1.5 Amp. See also 13 Pulse transformer unit (LA102800).


       There are terminals to accept an externally generated isolated armature current signal, field signal, thermal
heatsink sensor switch, and high voltage armature voltage feedback.

 

The unit also provides a +24V supply for the gate drive pulse transformers that is short circuit protected.
 

The following stack configurations can be driven by the PL/XD.
 

1) 6 pulse 2 Quadrant bridge (6 thyristors), or 2 bridges in parallel (12 thyristors).
 

2) 6 pulse 4 Quadrant regen anti parallel bridge (12 thyristors).
     

Extra stacks can be used in parallel within the gate drive capability.
 

All customer control terminals are the plug in screw terminal variety.
 

The PL/XD can be used with up to 690V AC on its 3 phase auxiliary supply inputs (EL1/2/3). The external
stacks can be of higher voltages if required.
      

The armature voltage inputs can monitor up to +/-1000 Volts DC.
       

There is an integral motor field bridge with independant single phase AC supply inputs (EF2/3) for controlling
fields up to 32 Amps. The internal field bridge supply input voltage rating is 480V AC.
       

Provision is made for providing an external field feedback signal and controlling an external field with user
supplied primary gate pulse transformer drivers. See also13 Pulse transformer unit (LA102800).
       

Comprehensive details are included in this manual to assist the user in designing the external interface.
       

All transformer components (pulse tx, acct) that interface with high voltage circuits must have an isolation
voltage of at least 4 times AC volts plus 1000V.
       Eg for 480 volts AC, isolation voltage rating must be at least 2920 Volts.
       Also the interwinding capacitance must be as low as possible and not in excess of 10 picofarad between
primary and secondary.
      

 

There is a Pulse transformer unit (Product code LA102800) available at extra cost for users who prefer not to
supply their own components. It contains all the external interface components required to combine the
       PL/XD with the thyristor stack and its associated Accts (AC current transformers). It includes 12 pulse
transformer networks for 2 or 4 quadrant bridges, an armature burden rectifier network, and 2 pulse
transformer networks for an external field bridge. The unit is designed to be mounted on a DIN rail and all the
interface connections are via plug on screw terminals. See 13 Pulse transformer unit (LA102800).

 

 

 
 

 

公司地址:北京市西城区德胜门外教场口街1号9号楼230    100011    TEL:010-82081065/82088878     FAX:010-82085660    E-mail:XHCY@vip.sina.com

 

编号:京ICP备05016274号